ChemSpider 2D Image | Phenobarbital | C12H12N2O3

Phenobarbital

  • Molecular FormulaC12H12N2O3
  • Average mass232.235 Da
  • Monoisotopic mass232.084793 Da
  • ChemSpider ID4599

More details:



Featured data source



Validated by Experts, Validated by Users, Non-Validated, Removed by Users

2,4,6(1H,3H,5H)-Pyrimidinetrione, 5-ethyl-5-phenyl- [ACD/Index Name]
200-007-0 [EINECS]
4,6(1H,5H)-pyrimidinedione, 5-ethyl-2-hydroxy-5-phenyl-
50-06-6 [RN]
5-Ethyl-2-hydroxy-5-phenylpyrimidine-4,6(1H,5H)-dione
5-Ethyl-5-phenyl-2,4,6(1H,3H,5H)-pyrimidinetrione [ACD/IUPAC Name]
5-Éthyl-5-phényl-2,4,6(1H,3H,5H)-pyrimidinetrione [French] [ACD/IUPAC Name]
5-Ethyl-5-phenyl-2,4,6(1H,3H,5H)-pyrimidintrion [German] [ACD/IUPAC Name]
More...

Validated by Experts, Validated by Users, Non-Validated, Removed by Users

414 [DBID]
50--06--6 [DBID]
AI3-02726 [DBID]
AIDS018460 [DBID]
AIDS-018460 [DBID]
BAS 00226811 [DBID]
C07434 [DBID]
CCRIS 502 [DBID]
CHEBI:8069 [DBID]
D00506 [DBID]
More...
  • Experimental Physico-chemical Properties
  • Miscellaneous
  • Gas Chromatography
    • Retention Index (Kovats):

      2025 (estimated with error: 89) NIST Spectra mainlib_113836, replib_334474, replib_250543, replib_312826, replib_335473, replib_11142, replib_68990, replib_235665
      1965 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 0.6 m; Column type: Packed; Heat rate: 30 K/min; Start T: 100 C; End T: 310 C; End time: 5 min; Start time: 3 min; CAS no: 50066; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb G HP; Data type: Kovats RI; Authors: Maurer, H.H., Detection of anticonvulsants and their metabolites in urine within a "general unknown" analysis procedure using computerized gas chromatography-mass spectrometry, Arch. Toxicol., 64(7), 1990, 554-561., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 30 K/min; Start T: 100 C; End T: 310 C; End time: 5 min; Start time: 3 min; CAS no: 50066; Active phase: SE-30; Carrier gas: N2; Data type: Kovats RI; Authors: Maurer, H.H., Identification and differentiation of barbiturates, other sedative-hypnotics and their metabolites in urine integrated in a general screening procedure using computerized gas chromatography-mass spectrometry, J. Chromatogr., 530, 1990, 307-326.) NIST Spectra nist ri
      1931 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column diameter: 0.53 mm; Column length: 30 m; Column type: Capillary; Start T: 200 C; CAS no: 50066; Active phase: DB-1; Carrier gas: N2; Phase thickness: 1.5 um; Data type: Kovats RI; Authors: Japp, M.; Gill, R.; Osselton, M.D., Comparison of drug retention indices determined on packed, wide bore capillary and narrow bore capillary columns, J. Forensic Sci., 32(6), 1987, 1574-1586.) NIST Spectra nist ri
      1932 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column diameter: 0.22 mm; Column length: 25 m; Column type: Capillary; Start T: 200 C; CAS no: 50066; Active phase: BP-1; Carrier gas: N2; Phase thickness: 0.25 um; Data type: Kovats RI; Authors: Japp, M.; Gill, R.; Osselton, M.D., Comparison of drug retention indices determined on packed, wide bore capillary and narrow bore capillary columns, J. Forensic Sci., 32(6), 1987, 1574-1586.) NIST Spectra nist ri
      1937 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column diameter: 0.53 mm; Column length: 25 m; Column type: Capillary; Start T: 200 C; CAS no: 50066; Active phase: BP-1; Carrier gas: N2; Phase thickness: 1 um; Data type: Kovats RI; Authors: Japp, M.; Gill, R.; Osselton, M.D., Comparison of drug retention indices determined on packed, wide bore capillary and narrow bore capillary columns, J. Forensic Sci., 32(6), 1987, 1574-1586.) NIST Spectra nist ri
      1995 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column diameter: 0.20 mm; Column length: 25 m; Column type: Capillary; Start T: 250 C; CAS no: 50066; Active phase: SPB-1; Carrier gas: He; Data type: Kovats RI; Authors: Lora-Tamayo, C.; Rams, M.A.; Chacon, J.M.R., Gas Chromatographic Data for 187 Nitrogen- or Phosphorus-Containing Drugs and Metabolites of Toxicological Interest Analysed on Methyl Silicone Capillary Columns, J. Chromatogr., 374, 1986, 73-85.) NIST Spectra nist ri
      1938 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.49 mm; Column length: 25 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 100 C; End T: 275 C; End time: 15 min; Start time: 2 min; CAS no: 50066; Active phase: SE-30; Phase thickness: 1.14 um; Data type: Kovats RI; Authors: Schepers, P.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A., Applicability of capillary gas chromatography to substance identification in toxicology by means of retention indices, J. Forensic Sci., 27(1), 1982, 49-60.) NIST Spectra nist ri
      1939 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 300 C; End time: 12 min; Start time: 2 min; CAS no: 50066; Active phase: SE-30; Carrier gas: He; Phase thickness: 0.45 um; Data type: Kovats RI; Authors: Schepers, P.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A., Applicability of capillary gas chromatography to substance identification in toxicology by means of retention indices, J. Forensic Sci., 27(1), 1982, 49-60.) NIST Spectra nist ri
      1934 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column type: Packed; Start T: 200 C; CAS no: 50066; Active phase: SE-30; Data type: Kovats RI; Authors: Stead, A.H.; Gill, R.; Evans, A.T.; Moffat, A.C., Predictions of gas chromatographic retention characteristics of barbiturates from molecular structure, J. Chromatogr., 234, 1982, 277-283.) NIST Spectra nist ri
      1990 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 6 ft; Column type: Packed; CAS no: 50066; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb W; Data type: Kovats RI; Authors: McLinden, V.J.; Stenhouse, A.M., A chromatography system for drug identification, Forensic Sci. Int., 13, 1979, 71-79.) NIST Spectra nist ri
      1950 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 2 m; Column type: Packed; Start T: 200 C; CAS no: 50066; Active phase: OV-1; Substrate: Chromosorb G; Data type: Kovats RI; Authors: Dubsky, H.; Hana, K.; Komarkova, M.; Rittich, B., Pouziti kovatsovych indexu pri toxikologickych analysach, Chem. Listy, 72, 1978, 980-984., Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 6 ft; Column type: Packed; Start T: 200 C; CAS no: 50066; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb G AW DMCS (80-100 mesh); Data type: Kovats RI; Authors: Moller, M.R., Comparability of retention indices of polar substances at elevated temperatures, Chromatographia, 9(7), 1976, 311-314.) NIST Spectra nist ri
      1964 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 2 m; Column type: Packed; Start T: 180 C; CAS no: 50066; Active phase: OV-1; Substrate: Chromosorb G; Data type: Kovats RI; Authors: Dubsky, H.; Hana, K.; Komarkova, M.; Rittich, B., Pouziti kovatsovych indexu pri toxikologickych analysach, Chem. Listy, 72, 1978, 980-984.) NIST Spectra nist ri
      1955 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 6 ft; Column type: Packed; Start T: 200 C; CAS no: 50066; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb G AW DMCS (80-100 mesh); Data type: Kovats RI; Authors: Moller, M.R., Comparability of retention indices of polar substances at elevated temperatures, Chromatographia, 9(7), 1976, 311-314., Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column type: Packed; Start T: 200 C; CAS no: 50066; Active phase: OV-1; Data type: Kovats RI; Authors: Berninger, H.; Moller, M.R., Retentionsindices zur gaschromatographischen Identifizierung von Arzneimitteln, Arch. Toxicol., 37, 1977, 295-305.) NIST Spectra nist ri
      1960 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 6 ft; Column type: Packed; Start T: 200 C; CAS no: 50066; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb G AW DMCS (80-100 mesh); Data type: Kovats RI; Authors: Moller, M.R., Comparability of retention indices of polar substances at elevated temperatures, Chromatographia, 9(7), 1976, 311-314.) NIST Spectra nist ri
      1970 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 2 m; Column type: Packed; CAS no: 50066; Active phase: OV-1; Carrier gas: N2; Substrate: Chromosorb G, AW-DMCS; Data type: Kovats RI; Authors: Berninger, H.; Grunnagel, R.; Mall, S.; Moller, M.R., Gas chromatographic identification of unknown substances from body fluids by menas of retention indices, Beitr. Gerichtl. Med., 33, 1975, 185-191.) NIST Spectra nist ri
      1975 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 6 ft; Column type: Packed; CAS no: 50066; Active phase: OV-1; Carrier gas: N2; Substrate: Chromosorb G, AW-DMCS; Data type: Kovats RI; Authors: Berninger, H.; Grunnagel, R.; Mall, S.; Moller, M.R., Gas chromatographic identification of unknown substances from body fluids by menas of retention indices, Beitr. Gerichtl. Med., 33, 1975, 185-191.) NIST Spectra nist ri
      1984 (Program type: Isothermal; Col... (show more) umn class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Start T: 220 C; CAS no: 50066; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.2 um; Data type: Kovats RI; Authors: Phillips, A.M.; Logan, B.K.; Stafford, D.T., Further applications for capillary gas chromatography in routine quantitative toxicological analyses, J. Hi. Res. Chromatogr., 13, 1990, 754-758.) NIST Spectra nist ri
    • Retention Index (Normal Alkane):

      1934 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Capillary; Start T: 100 C; End T: 300 C; CAS no: 50066; Active phase: BP-1; Data type: Normal alkane RI; Authors: MHA, Directorate of ForensicScience., Forensic Toxicology, 9999.) NIST Spectra nist ri
      1956 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.75 mm; Column length: 30 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 155 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 50066; Active phase: SPB-1; Carrier gas: He; Phase thickness: 10 um; Data type: Normal alkane RI; Authors: Coudore, F.; Alazard, J.-M.; Paire, M.; Andraud, G.; Lavarenne, J., Rapid toxicological screening of barbiturates in plasma by wide-bore capillary gas chromatography and nitrogen-phosphorus detection, J. Anal. Toxicol., 17, 1993, 109-113.) NIST Spectra nist ri
      1960.9 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.32 mm; Column length: 12 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 40 C; End T: 290 C; Start time: 1 min; CAS no: 50066; Active phase: SE-30; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Neill, G.P.; Davies, N.W.; McLean, S., Automated screening procedure using gas chromatography-mass spectrometry for identification of drugs after their extraction from biological samples, J. Chromatogr., 565, 1991, 207-224.) NIST Spectra nist ri
      1919.5 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.26 mm; Column length: 30 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 280 C; End time: 22 min; Start time: 1 min; CAS no: 50066; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Manca, D.; Ferron, L.; Weber, J-P., A System for Toxicological Screening by Capillary Gas Chromatography with Use of Drug Retention Index Based on Nitrogen-Containing Reference Compounds, Clin. Chem., 35(4), 1989, 601-607.) NIST Spectra nist ri
      1957 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.53 mm; Column length: 10 m; Column type: Capillary; CAS no: 50066; Active phase: CP Sil 5 CB; Phase thickness: 5.2 um; Data type: Normal alkane RI; Authors: Bogusz, M.; Bialka, J.; Gierz, J.; Klys, M., Use of short, wide-bore capillary columns in GC toxicological screening, J. Anal. Toxicol., 10(4), 1986, 135-138., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Capillary; Heat rate: 16 K/min; Start T: 200 C; End T: 280 C; CAS no: 50066; Active phase: OV-1; Data type: Normal alkane RI; Authors: Schutz, H.; Wollrab A., The significance of the retention index in toxicologic analysis II, Pharmazie in unzerer Zeit, 17(4), 1988, 97-101., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column type: Other; CAS no: 50066; Active phase: Methyl Silicone; Data type: Normal alkane RI; Authors: Ardrey, R.E.; Moffat, A.C., Gas-liquid chromatographic retention indices of 1318 substances of toxicological interest on SE-30 or OV-1 stationary phase, J. Chromatogr., 220, 1981, 195-252.) NIST Spectra nist ri
      1926 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 130 C; End T: 290 C; End time: 10 min; Start time: 1 min; CAS no: 50066; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Sharp, M.E., A rapid screening procedure for acidic and neutral drugs in blood by high resolution gas chromatography, J. Anal. Toxicol., 11, 1987, 8-11.) NIST Spectra nist ri
      1980 (Program type: Complex; Column... (show more) class: Standard non-polar; Column diameter: 0.53 mm; Column length: 10 m; Column type: Capillary; Description: 100 0C (2 min) ^ 20 0C/min -> 180 0C ^ 7.5 0C/min -> 280 0C (6 min); CAS no: 50066; Active phase: CP Sil 5 CB; Phase thickness: 5.2 um; Data type: Normal alkane RI; Authors: Bogusz, M.; Bialka, J.; Gierz, J.; Klys, M., Use of short, wide-bore capillary columns in GC toxicological screening, J. Anal. Toxicol., 10(4), 1986, 135-138.) NIST Spectra nist ri
      1922 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Heat rate: 20 K/min; Start T: 50 C; End T: 300 C; CAS no: 50066; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32.) NIST Spectra nist ri
      1924 (Program type: Complex; Column... (show more) class: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Description: 120 0X ^ 8 0C/min -> 270 0C ^ 25 0C/min -> 300 0C (5 min); CAS no: 50066; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32.) NIST Spectra nist ri
      1928 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 280 C; CAS no: 50066; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32.) NIST Spectra nist ri
      1950 (Program type: Isothermal; Col... (show more) umn class: Standard non-polar; Column length: 6 ft; Column type: Packed; Start T: 200 C; CAS no: 50066; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb G AW DMCS (80-100 mesh); Data type: Normal alkane RI; Authors: Moller, M.R., Comparability of retention indices of polar substances at elevated temperatures, Chromatographia, 9(7), 1976, 311-314., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; CAS no: 50066; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32.) NIST Spectra nist ri
      1935 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 2 m; Column type: Packed; Heat rate: 2.5 K/min; Start T: 120 C; End T: 200 C; CAS no: 50066; Active phase: SE-30; Substrate: Gas Chrom P; Data type: Normal alkane RI; Authors: Marozzi, E.; Gambaro, V.; Saligari, E.; Mariani, R.; Lodi, F., Use of the retention index in gas chromatographic studies of drugs, J. Anal. Toxicol., 6, 1982, 185-192.) NIST Spectra nist ri
      1941.2 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 2 m; Column type: Packed; Heat rate: 10 K/min; Start T: 220 C; End T: 270 C; CAS no: 50066; Active phase: OV-101; Substrate: Chromosorb (100-120 mesh); Data type: Normal alkane RI; Authors: Cailleux, A.; Turcant, A.; Premel-Cabic, A.; Allain, P., Identification and Quantitation of Neutral and Basic Drugs in Blood By Gas Chromatography and Mass Spectrometry, J. Chromatogr. Sci., 19, 1981, 163-176.) NIST Spectra nist ri
      1975 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 6 ft; Column type: Packed; Heat rate: 8 K/min; Start T: 130 C; End T: 290 C; End time: 8 min; Start time: 2 min; CAS no: 50066; Active phase: SE-30; Carrier gas: N2; Substrate: Chromosorb W AW DMS; Data type: Normal alkane RI; Authors: Peel, H.W.; Perrigo, B., A practical gas chromatographic screening procedure for toxicological analysis, Can.Soc.Forens.Sci.J., 9(2), 1975, 69-74., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 6 ft; Column type: Packed; Heat rate: 8 K/min; Start T: 130 C; End T: 290 C; End time: 8 min; Start time: 2 min; CAS no: 50066; Active phase: SE-30; Carrier gas: Nitrogen; Substrate: Chromosorb W AW DMS (80-100 mesh); Data type: Normal alkane RI; Authors: Peel, H.W.; Perrigo, B., A practical gas chromatographic screening procedure for toxicological analysis, Can. Soc. Forens. Sci. J., 9(2), 1976, 69-74.) NIST Spectra nist ri
      1996 (Program type: Ramp; Column cl... (show more) ass: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 30 m; Column type: Capillary; Heat rate: 15 K/min; Start T: 80 C; End T: 295 C; End time: 8 min; Start time: 1 min; CAS no: 50066; Active phase: SE-54; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Friel, P.N.; Logan, B.K.; Formoso, E.J., GC-MS analysis and post-mortem distribution of felbamate in humans, J. Epilepsy, 10, 1997, 283-286.) NIST Spectra nist ri
      1922.7 (Program type: Ramp; Column cl... (show more) ass: Semi-standard non-polar; Column diameter: 0.34 mm; Column length: 18 m; Column type: Capillary; Heat rate: 25 K/min; Start T: 100 C; End T: 275 C; End time: 5 min; Start time: 2 min; CAS no: 50066; Active phase: CP Sil 8 CB; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: de Baere, S.M.; Lambert, W.E.; van Bocxlaer, J.F.; de Leenheer, A.P., Quantitative gas chromatographic analysis of 3-cyano-3,3-diphenylpropionic acid, the acidic metabolite of bezitramide (Burgodin), in urine, J. Anal. Toxicol., 20, 1996, 159-164.) NIST Spectra nist ri
      1975.4 (Program type: Ramp; Column cl... (show more) ass: Semi-standard non-polar; Column diameter: 0.53 mm; Column length: 12 m; Column type: Capillary; Heat rate: .5 K/min; Start T: 100 C; End T: 310 C; End time: 10 min; Start time: 2 min; CAS no: 50066; Active phase: DB-5; Carrier gas: He; Phase thickness: 1.0 um; Data type: Normal alkane RI; Authors: Drummer, O.H.; Horomidis, S.; Kourtis, S.K.; Syrjanen, M.L.; Tippet, P., Capillary gas chromatographic drug screen for use in forensic toxicology, J. Anal. Toxicol., 18, 1994, 134-138.) NIST Spectra nist ri
      1986.1 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 25 m; Column type: Capillary; Description: 70 0C (0.7 min) ^ 20 0C/min -> 140 0C ^ 10 0C/min -> 280 0C (4 min); CAS no: 50066; Active phase: NB-54; Carrier gas: He; Phase thickness: 0.10 um; Data type: Normal alkane RI; Authors: Ojanpera, I.; Rasanen, I.; Vuori, E., Automated quantitative screening for acidic and neutral drugs in whole blood by dual-column capillary gas chromatography, J. Anal. Toxicol., 15, 1991, 204-208.) NIST Spectra nist ri
      1961.7 (Program type: Ramp; Column cl... (show more) ass: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 12.5 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 110 C; End T: 290 C; End time: 6.5 min; Start time: 1 min; CAS no: 50066; Active phase: Ultra-2; Phase thickness: 0.5 um; Data type: Normal alkane RI; Authors: Watts, V.W.; Simonick, T.F., A retention index library for commonly encountered drugs and metabolites using tri-n-alkylamines as reference compounds, nitrogen-phosphorus detectors, and dual capillary chromatography, J. Anal. Toxicol., 11, 1987, 210-214.) NIST Spectra nist ri
    • Retention Index (Linear):

      1944 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.75 mm; Column length: 30 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 160 C; End T: 280 C; End time: 12 min; CAS no: 50066; Active phase: SPB-1; Carrier gas: He; Phase thickness: 1.0 um; Data type: Linear RI; Authors: Christ, D.W.; Noomano, P.; Rosas, M.; Rhone, D., Retention indices by wide-bore capillary gas chromatography with nitrogen-phosphorus detection, J. Anal. Toxicol., 12, 1988, 84-88.) NIST Spectra nist ri
      1910 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.53 mm; Column length: 12 m; Column type: Capillary; Heat rate: 6 K/min; Start T: 120 C; End T: 250 C; CAS no: 50066; Active phase: CBP-1; Carrier gas: N2; Data type: Linear RI; Authors: Oyama, N.; Sano, T.; Syoyama, M.; Maeda, K., Studies on systematic analysis of poisonous compounds in forensic chemistry. II. Application of capillary column gas chromatography to substance identification by means of retention indices, Eisei Kagaku, 33(5), 1987, 342-348.) NIST Spectra nist ri
      1924 (Program type: Complex; Column... (show more) class: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Description: 120C=>8C/min=>270C=>25C/min=>300C; CAS no: 50066; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Stowell, A.; Wilson, L.W., A simple approach to the interlaboratory transfer of drug retention indices determined by temperature programmed capillary gas chromatography, J. Forensic Sci., 32(5), 1987, 1214-1220.) NIST Spectra nist ri
      1928 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 280 C; End time: 5 min; CAS no: 50066; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Perrigo, B.J.; Ballantyne, D.J.; Peel, H.W., Condierations in developing a data base for drugs on a DBI capillary column, J. Can. Soc. Forensic Sci., 17(2), 1984, 41-49., Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.32 mm; Column length: 15 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 280 C; End time: 5 min; CAS no: 50066; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Perrigo, B.J.; Peel, H.W.; Ballantyne, D.J., Use of Dual-Column Fused-Silica Capillary Gas Chromatography in Combination with Detector Response Factors for Analytical Toxicology., J. Chromatogr., 341, 1985, 81-88.) NIST Spectra nist ri
      1921.5 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column diameter: 0.2 mm; Column length: 12 m; Column type: Capillary; Heat rate: 20 K/min; Start T: 50 C; End T: 300 C; End time: 3 min; Start time: 1 min; CAS no: 50066; Active phase: Methyl Silicone; Carrier gas: He; Phase thickness: 0.33 um; Data type: Linear RI; Authors: Newton, B.; Foery, R.F., Retention indices and dual capillary gas chromatography for rapid identification of sedative hypnotic drugs in emergency toxicology, J. Anal. Toxicol., 8, 1984, 129-134.) NIST Spectra nist ri
      1975 (Program type: Ramp; Column cl... (show more) ass: Standard non-polar; Column length: 1.8 m; Column type: Packed; Heat rate: 8 K/min; Start T: 130 C; End T: 290 C; End time: 8 min; Start time: 2 min; CAS no: 50066; Active phase: SE-30; Carrier gas: N2; Substrate: Chromosorb W; Data type: Linear RI; Authors: Perrigo, B.J.; Peel, H.W., The use of retention indices and temperature-programmed gas chromatography in analytical toxicology, J. Chromatogr. Sci., 19, 1981, 219-226.) NIST Spectra nist ri
      2028.4 (Program type: Complex; Column... (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: Multi-step temperature program; T(initial)=60C; T(final)=270C; CAS no: 50066; Active phase: VF-5MS; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Tret'yakov, K.V., Retention Data. NIST Mass Spectrometry Data Center., 2008.) NIST Spectra nist ri
      1995 (Program type: Ramp; Column cl... (show more) ass: Semi-standard non-polar; Column diameter: 0.2 mm; Column length: 12 m; Column type: Capillary; Heat rate: 20 K/min; Start T: 50 C; End T: 300 C; End time: 3 min; Start time: 1 min; CAS no: 50066; Active phase: 5 % Phenyl methyl siloxane; Carrier gas: He; Phase thickness: 0.33 um; Data type: Linear RI; Authors: Newton, B.; Foery, R.F., Retention indices and dual capillary gas chromatography for rapid identification of sedative hypnotic drugs in emergency toxicology, J. Anal. Toxicol., 8, 1984, 129-134.) NIST Spectra nist ri

Predicted data is generated using the ACD/Labs Percepta Platform - PhysChem Module, version: 14.00

Density: 1.2±0.1 g/cm3
Boiling Point:
Vapour Pressure:
Enthalpy of Vaporization:
Flash Point:
Index of Refraction: 1.542
Molar Refractivity: 59.2±0.3 cm3
#H bond acceptors: 5
#H bond donors: 2
#Freely Rotating Bonds: 2
#Rule of 5 Violations: 0
ACD/LogP: 1.67
ACD/LogD (pH 5.5): 1.40
ACD/BCF (pH 5.5): 6.83
ACD/KOC (pH 5.5): 137.39
ACD/LogD (pH 7.4): 1.19
ACD/BCF (pH 7.4): 4.17
ACD/KOC (pH 7.4): 83.78
Polar Surface Area: 75 Å2
Polarizability: 23.5±0.5 10-24cm3
Surface Tension: 43.3±3.0 dyne/cm
Molar Volume: 188.2±3.0 cm3

Predicted data is generated using the US Environmental Protection Agency�s EPISuite™

                        
 Log Octanol-Water Partition Coef (SRC):
    Log Kow (KOWWIN v1.67 estimate) =  1.33
    Log Kow (Exper. database match) =  1.47
       Exper. Ref:  Hansch,C et al. (1995)

 Boiling Pt, Melting Pt, Vapor Pressure Estimations (MPBPWIN v1.42):
    Boiling Pt (deg C):  568.79  (Adapted Stein & Brown method)
    Melting Pt (deg C):  244.73  (Mean or Weighted MP)
    VP(mm Hg,25 deg C):  1.36E-011  (Modified Grain method)
    MP  (exp database):  174 deg C
    Subcooled liquid VP: 4.77E-010 mm Hg (25 deg C, Mod-Grain method)

 Water Solubility Estimate from Log Kow (WSKOW v1.41):
    Water Solubility at 25 deg C (mg/L):  1644
       log Kow used: 1.47 (expkow database)
       no-melting pt equation used
     Water Sol (Exper. database match) =  1110 mg/L (25 deg C)
        Exper. Ref:  YALKOWSKY,SH & DANNENFELSER,RM (1992)

 Water Sol Estimate from Fragments:
    Wat Sol (v1.01 est) =  735.08 mg/L
    Wat Sol (Exper. database match) =  1110.00
       Exper. Ref:  YALKOWSKY,SH & DANNENFELSER,RM (1992)

 ECOSAR Class Program (ECOSAR v0.99h):
    Class(es) found:
       Imides

 Henrys Law Constant (25 deg C) [HENRYWIN v3.10]:
   Bond Method :   1.65E-014  atm-m3/mole
   Group Method:   Incomplete
 Henrys LC [VP/WSol estimate using EPI values]:  2.528E-015 atm-m3/mole

 Log Octanol-Air Partition Coefficient (25 deg C) [KOAWIN v1.10]:
  Log Kow used:  1.47  (exp database)
  Log Kaw used:  -12.171  (HenryWin est)
      Log Koa (KOAWIN v1.10 estimate):  13.641
      Log Koa (experimental database):  None

 Probability of Rapid Biodegradation (BIOWIN v4.10):
   Biowin1 (Linear Model)         :   0.5811
   Biowin2 (Non-Linear Model)     :   0.4469
 Expert Survey Biodegradation Results:
   Biowin3 (Ultimate Survey Model):   2.4958  (weeks-months)
   Biowin4 (Primary Survey Model) :   3.3641  (days-weeks  )
 MITI Biodegradation Probability:
   Biowin5 (MITI Linear Model)    :   0.1798
   Biowin6 (MITI Non-Linear Model):   0.0612
 Anaerobic Biodegradation Probability:
   Biowin7 (Anaerobic Linear Model):  0.1893
 Ready Biodegradability Prediction:   NO

Hydrocarbon Biodegradation (BioHCwin v1.01):
    Structure incompatible with current estimation method!

 Sorption to aerosols (25 Dec C)[AEROWIN v1.00]:
  Vapor pressure (liquid/subcooled):  6.36E-008 Pa (4.77E-010 mm Hg)
  Log Koa (Koawin est  ): 13.641
   Kp (particle/gas partition coef. (m3/ug)):
       Mackay model           :  47.2 
       Octanol/air (Koa) model:  10.7 
   Fraction sorbed to airborne particulates (phi):
       Junge-Pankow model     :  0.999 
       Mackay model           :  1 
       Octanol/air (Koa) model:  0.999 

 Atmospheric Oxidation (25 deg C) [AopWin v1.92]:
   Hydroxyl Radicals Reaction:
      OVERALL OH Rate Constant =  10.1056 E-12 cm3/molecule-sec
      Half-Life =     1.058 Days (12-hr day; 1.5E6 OH/cm3)
      Half-Life =    12.701 Hrs
   Ozone Reaction:
      No Ozone Reaction Estimation
   Fraction sorbed to airborne particulates (phi): 1 (Junge,Mackay)
    Note: the sorbed fraction may be resistant to atmospheric oxidation

 Soil Adsorption Coefficient (PCKOCWIN v1.66):
      Koc    :  245.6
      Log Koc:  2.390 

 Aqueous Base/Acid-Catalyzed Hydrolysis (25 deg C) [HYDROWIN v1.67]:
    Rate constants can NOT be estimated for this structure!

 Bioaccumulation Estimates from Log Kow (BCFWIN v2.17):
   Log BCF from regression-based method = 0.432 (BCF = 2.703)
       log Kow used: 1.47 (expkow database)

 Volatilization from Water:
    Henry LC:  1.65E-014 atm-m3/mole  (estimated by Bond SAR Method)
    Half-Life from Model River: 5.408E+010  hours   (2.253E+009 days)
    Half-Life from Model Lake : 5.899E+011  hours   (2.458E+010 days)

 Removal In Wastewater Treatment:
    Total removal:               1.96  percent
    Total biodegradation:        0.09  percent
    Total sludge adsorption:     1.87  percent
    Total to Air:                0.00  percent
      (using 10000 hr Bio P,A,S)

 Level III Fugacity Model:
           Mass Amount    Half-Life    Emissions
            (percent)        (hr)       (kg/hr)
   Air       8.5e-005        25.4         1000       
   Water     33.5            900          1000       
   Soil      66.4            1.8e+003     1000       
   Sediment  0.0832          8.1e+003     0          
     Persistence Time: 1.18e+003 hr




                    

Click to predict properties on the Chemicalize site






Advertisement